Crane mount needs to be modified to not connect to the Enclosure.
Utility level
...
cable wrap
Dust causes cables to bind.
Cables need to be cleaned on PM. Cables need cleaning.
Delta chain has excess slack. Needs
Cables need to be
...
adjusted.
Air Knife
Air knife is vibration concern.
Enclosure cable wrap
Enclosure cable wrap rollers can rust and siezeseize. Causes dragging and vibration. Can detect by seeing scratches on the wrap bed.
Need to inspect cable wrap rollers on PM.
Need to inspect truck rollers on PM.
Cables and slots need to be cleaned on PM.
There's a Heidenhain an alignment fixture and control unit for the Heidenhain encoder.
Need to locate alignment fixture and control unit
...
.
There's a procedure to align mount motor gear to the drive wheel somewhere. Also must adjust commutation of the drive.
Need to locate the alignment procedure.
Telescope level
Cooler cabinet is hard bolted to deck without .
Need to install vibration isolation.
Mount has multi position locking pins. 2 pin positions, check for balance before removing pin.
Need to locate the locking pin documentation an procedure.
Shutter crawlers should be greased on PM.
Enclosure azimuth lightning brushes resistance should be checked on PM.