Enclosure Azimuth motion is controlled by the EMCS PLC. Motion is commanded from the ECS or locally.

ECS can control motion in four modes

  • Tracking - ECS sends Position Reference and Speed Reference

  • Point to Point - ECS sends Position Reference and sometimes sends Speed Reference

  • Jogging and Offset - modes are not used

Local motion includes Point to Point and Jogging

EMCS PLC controls Enclosure Azimuth motion in these routines

  • EMCS Azimuth / Control Speed

  • EMCS Azimuth / Control Loop