Safety Function

Light Path

Hazard

Focused sunlight along optical path

Triggering Event

Any of the following:

  • TEOA Safety Function activated:

    • Heat Stop over temperature

    • Heat Absorber over temperature

    • Heat Stop low coolant flow

    • Safety shutter not fully stowed

  • Telescope Altitude permissive removed

  • Telescope Azimuth permissive removed

  • M1 Cover UPS failure

  • Aperture cover drive ‘not ready’

  • Separation angle between Sun and optical path > 1.5R

  • Heat Stop fuse wire not OK

  • Instrument Field-of-view misconfigured

Priority

The Light Path shall take priority over all other control functions.

Modes

When light path is not blocked

  • Sun above the horizon and

  • Enclosure Aperture pointing within 25° of the Sun

Reaction

Block light path using sequence:

Close M1 Cover then

Close Aperture Cover

Safe State

Aperture Cover closed

M1 Mirror Cover closed

Required Integrity

SIL2

...