Skip to end of banner
Go to start of banner

Enclosure Azimuth Position Control

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Enclosure Azimuth motion is controlled by the EMCS PLC. Motion is commanded from the ECS or locally.

ECS can control motion in four modes

  • Tracking - ECS sends Position Reference and Speed Reference

  • Point to Point - ECS sends Position Reference and sometimes sends Speed Reference

  • Jogging and Offset - modes are not used

Local motion includes Point to Point and Jogging

EMCS PLC controls Enclosure Azimuth motion in these routines

  • EMCS / Azimuth / Control Speed
    Setup Control Loop:
    Position and Speed Reference
    Position Error control modes
    Tuning parameters
    Speed limits
    Response times

  • EMCS / Azimuth / Control Loop
    Calculate Speed Reference to Azimuth Drives for Position Control or Speed Control

EMCS PLC controls Enclosure Azimuth motion in two modes

  • Position Control
    Operate to maintain Actual Position = Position Reference

  • Speed Control
    Operate to move Azimuth at Speed Reference

Position Control

PI (Proportional / Integral) closed loop control

  • No labels