Clock | Identity | Class | Accuracy | Priority 1 Master Override | Priority 2 Tiebreaker |
---|---|---|---|---|---|
GMC1 | 000CECFFFE0A2BA1 | 6 | 33 | 125 | 50 |
GMC2 | 000CECFFFE0A2240 | 6 | 33 | 126 | 100 |
S4A-C9300-01 | 703509FFFE7F2200 |
|
|
|
|
GIC_switch | E49069FFFE0E9580 | 248 | 254 | 128 | 112 |
GIC_R00_S02_ENET | 001D9CFFFEBFFCF7 | 248 | 254 | 128 | 128 |
GIC_R00_S03_ENET | 001D9CFFFEBF28DF | 248 | 254 | 128 | 128 |
GIC_GLX | FFFF000100701AA1 | 248 | 254 | 128 | 129 |
TEL_switch | E49069FFFE100400 | 248 | 254 | 128 | 113 |
TEL_R00_S02_ENET | 001D9CFFFEBFFCF7 | 248 | 254 | 128 | 128 |
TEL_GLX | 086195FFFED306C4 | 187 | 48 | 128 | 129 |
ROT_switch | E49069FFFE155E80 | 248 | 254 | 128 | 114 |
ROT_R00_S02_ENET | 0000BCFFFEC97CAA | 248 | 254 | 128 | 128 |
ROT_GLX | FFFF0001007FD525 | 187 | 49 | 255 | 255 |
OSS_Switch | E49069FFFE100400 | 248 | 254 | 128 | 115 |
OSS_R00_S02_ENET | 001D9CFFFEBE3B25 | 248 | 254 | 128 | 128 |
OSS_GLX | FFFF00010070BA6D | 187 | 49 | 255 | 255 |
INST_Switch | 0000BCFFFE7D3F80 | 248 | 254 | 128 | 116 |
INST_R00_S02_ENET | 0000BCFFFEC488D6 | 248 | 254 | 128 | 128 |
INST_GLX | FFFF00010070B800 | 187 | 49 | 255 | 255 |
ENC_Switch1 | 0E9069FFFE04C380 | 248 | 254 | 128 | 117 |
ENC_Switch2 | E49069FFFE04C200 | 248 | 254 | 128 | 121 |
ENC_R00_S01_ENET | 001D9CFFFEBD70C5 | 248 | 254 | 128 | 128 |
ENC_R00_S02_ENET | 001D9CFFFEBD8955 | 248 | 254 | 128 | 128 |
ENC_R00_S03_ENET | 001D9CFFFEBD89B8 | 248 | 254 | 128 | 128 |
ENC_GLX | FFFF0001008C9D15 | 187 | 49 | 255 | 128 |
EMCS_CLX | FFFF0001008FBC75 | 187 | 49 | 255 | 128 |
|
|
|
|
|
|
Class
clockClass |
|
---|---|
6 | clock is synchronized to a primary reference time source |
7 | clock that has previously been designated as clockClass 6 but that has lost the ability to synchronize to a primary reference time source and is in holdover mode and within holdover specifications |
52 | Degradation alternative A for a clock of clockClass 7 that is not within holdover specification. A clock of clockClass 52 shall not be a slave to another clock in the domain. |
187 | Degradation alternative B for a clock of clockClass 7 that is not within holdover specification. A clock of clockClass 187 may be a slave to another clock in the domain. |
248 | Default |
255 | Slave only |
Accuracy
Value (Dec) | Value (Hex) | Specification |
---|---|---|
32 | 0x20 | The time is accurate to within 25 ns |
33 | 0x21 | The time is accurate to within 100 ns |
34 | 0x22 | The time is accurate to within 250 ns |
35 | 0x23 | The time is accurate to within 1 μs |
36 | 0x24 | The time is accurate to within 2.5 μs |
37 | 0x25 | The time is accurate to within 10 μs |
38 | 0x26 | The time is accurate to within 25 μs |
39 | 0x27 | The time is accurate to within 100 μs |
40 | 0x28 | The time is accurate to within 250 μs |
41 | 0x29 | The time is accurate to within 1 ms |
42 | 0x2A | The time is accurate to within 2.5 ms |
43 | 0x2B | The time is accurate to within 10 ms |
44 | 0x2C | The time is accurate to within 25 ms |
45 | 0x2D | The time is accurate to within 100 ms |
46 | 0x2E | The time is accurate to within 250 ms |
47 | 0x2F | The time is accurate to within 1 s |
48 | 0x30 | The time is accurate to within 10 s |
49 | 0x31 | The time is accurate to >10 s |
254 | 0FE | Unknown |