Enclosure Azimuth motion is controlled by the EMCS PLC. Motion is commanded from the ECS or locally.
ECS can control motion in four modes
Tracking - ECS sends Position Reference and Speed Reference
Point to Point - ECS sends Position Reference and sometimes sends Speed Reference
Jogging and Offset - modes are not used
Local motion includes Point to Point and Jogging
EMCS PLC controls Enclosure Azimuth motion in these routines
EMCS / Azimuth / Control Speed
Setup Control Loop:
Position and Speed Reference
Position Error control modes
Tuning parameters
Speed limits
Response timesEMCS / Azimuth / Control Loop
Calculate Speed Reference to Azimuth Drives for Position Control or Speed Control
EMCS PLC controls Enclosure Azimuth motion in two modes
Position Control
Operate to maintain Actual Position = Position ReferenceSpeed Control
Operate to move Azimuth at Speed Reference
Position Control
PI (Proportional / Integral) closed loop control