Skip to end of banner
Go to start of banner

Troubleshooting

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

This page is to help identify issues with the operation on the telescope and corrective action.

1

4/19/22

Mount did not go active

Aborted-Error 2

az failed with error(-14) controller interlocked

alt failed with error(-14) controller interlocked

Beckhoff error: external error

Reset Phase guard in MDC2 (service ring) cycle 3p circuit breaker above unit.

Phase guard was replaced 7/26/21 continue to monitor.

2

4/19/22

M3 fault

aborted- Hardware exceeption when setting PI E-712 servo mode

Reset PI controller in PA&C rack.

IT working on ports may have caused issue.

3

4/19/22

Pflow Coude door stuck open

Pflow Coude lab Roll up door doesn’t close (stuck open)

Re-stripped switch wires and terminate

Switch wires oxidized

4

Mount Motor Drive Fault.

MDC2 Phase Guard fault. Reset and it cleared.

  • No labels