Access to Enclosure Catwalks during observing

Access to Enclosure Catwalks during observing

Removing the trapped keys to access the Enclosure Catwalks during observing will cause the GIS to command the enclosure into a safe state. This is by design. It prevents inadvertent access to various hazardous locations while the enclosure is in motion.

To gain access, first complete a JHA and discuss this with supervisors and safety personnel.

Failure to follow procedures may result in serious injury or death.

  1. Close M1 Cover (optionally Aperture Cover could be closed).

  2. Stop Enclosure motion (if needed).

  3. Remove trapped keys to gain access (in this case A->B->C).

  4. Personnel safely access catwalk.

  5. Close gate. Return trapped keys C->B->A.

  6. Reset GIS (if needed).

  7. Resume tracking the Sun. (Enclosure: reset, then re-enable drives, begin tracking)

  8. Open the M1 Cover (or Aperture Cover).

  9. Perform tasks as needed.

  10. Close M1 Cover (optionally Aperture Cover could be closed).

  11. Remove trapped keys to gain access (in this case A->B->C).

  12. Personnel safely leave catwalk.

  13. Close gate. Return trapped keys C->B->A.

  14. Reset GIS (if needed).

  15. Resume tracking the Sun. (Enclosure: reset, then re-enable drives, begin tracking)

  16. Open the M1 Cover (or Aperture Cover).

Related content

M1 Cover Fault during closing
M1 Cover Fault during closing
More like this
DRAFT: How to Access the Coude Lab via Trapped Keys
DRAFT: How to Access the Coude Lab via Trapped Keys
More like this
Enclosure Safety Functions
Enclosure Safety Functions
More like this
Trapped Keys
More like this
GIS Overview
More like this
Coude Trapped Key Maps
Coude Trapped Key Maps
More like this