Coude Load Sensing System - Data Capture Procedure

Coude Load Sensing System - Data Capture Procedure

Data capture is gathered during the period of Coude Shake and Bake and may be conducted before or after official shake and bake has been completed.

Setup

Open the latest Coude LIC program so you have the ability to toggle the measure/reset signal. Under the “Load Sensor” routine, the “measure” signal is an active high signal to the charge amplifier. Toggle low/off to initiate a reset and turn hi/on to measure.

The latest Coude LIC program is located here:https://www.dropbox.com/scl/fo/o59pzk6p7xfkdi1rp8y2t/AONHZ2fQmUGoiGZ99iQleDg?rlkey=wvqvp53jfb2qrmuldplt8ddcy&st=5krrtsgq&dl=0

image-20250127-183350.png
Coude LIC - Load Sensor Routine

Open Ignition and start any application and bring up ad hoc chart from the new project tab, drag the following tags onto the graph for plotting: load_raw_voltage & p_ist_mult. The “load_raw_voltage” tag is found FMSRealtime>rodell test tags. The “p_ist_mult” tag is found FMSRealtime>coude encoder tracking>azimuth.

 

image-20250127-190000.png
Tags to Graph

For the Coude azimuth motion have the operator set the velocity to 0.25°/sec, and set travel position for 1 full rotation (0° to 360°).

When ready to execute the test run ensure the measure signal is on and execute motion, mark the start and stop times. (Duration of test should be 24 minutes.)

By the end of the test run the chart should look like this:

Make the upper bound 10,000 and the lower bound -10,000. Zoom into the graph to encase all the points from the start to stop time. Save the zoomed in graph into a .xlsx and rename to related OCP Coude Shake & Bake period and date. (example: OCP2.9_CoudeSB_ForceData_20240923)

Once saved use the following Jira ticket to archive the data file:

Analysis

The newest data set should look very similar to the previous data set, a quick comparison should be done and ensure no new higher peaks have not appeared. The data is made available to the mechanical group to decide if adjusts are needed. The last adjustments where made in March 2024, see the following:

Related content

Coude Load Sensing System - Overview
Coude Load Sensing System - Overview
More like this
Coude Azimuth Display
Coude Azimuth Display
More like this
Collect motor data for Mount drives
Collect motor data for Mount drives
More like this
Coude Trapped Key Maps
Coude Trapped Key Maps
More like this
Coude Rotator Hard Stops
Coude Rotator Hard Stops
More like this